Computer & IT advice

Test and Tag Failures: Real Faults We Found on Site

Crushed welder leads, exposed wires and failed power boards: real test and tag failures from local workplaces, why each one failed and how to prevent them.
Updated

Most test and tag failures are visible before the tester is even plugged in. Crushed leads, cuts that expose the inner wires, cracked plugs and worn-out power boards account for the majority of items we tag out of service. The photos below are all from recent test and tag jobs, and every one of these items was still in use when we arrived.

If you are wondering whether test and tag is worth doing, this is the reason: none of these faults were obvious to the people using the equipment every day.

Crushed and squashed leads

Squashed welder lead that failed test and tag
A welder lead that failed after being squashed most likely run over or caught under heavy gear

Workshop and welding leads take a beating. They are dragged across concrete, run over by trolleys and forklifts, and trapped under steel. Once a lead has been crushed, the insulation between the conductors can be damaged inside the sheath even when the outside looks only flattened. That is exactly the kind of fault that can turn the metal case of a tool live.

Damaged welder power lead that failed test and tag inspection
Another welder power lead tagged out of service

How to prevent it: run leads overhead or along walls where possible, use cable covers where they must cross a walkway or driveway, and coil leads properly rather than leaving them on the floor.

Exposed wires

Power lead with exposed internal wires found during test and tag
Inner wires showing through the outer sheath of a power lead

When the outer sheath of a lead is cut or worn through, the coloured inner conductors are only protected by their own thin insulation. One more nick and someone is touching a live wire. Electrical tape is not a repair: under AS/NZS 3760, a lead with damaged outer sheathing fails inspection.

Three-phase lead with exposed wires that failed test and tag
A three phase lead with exposed wiring Three phase equipment carries a higher voltage and a higher risk

Three-phase equipment such as compressors, welders and larger machinery is often left off a testing program because people assume it is fixed wiring. If it plugs in, it needs inspecting and testing like any other appliance, and we test 3-phase equipment as part of a normal visit.

Old and overloaded extension leads

Extension lead that failed test and tag inspection
An extension lead that failed inspection
Old extension lead removed from service after failing test and tag
An old extension lead removed from service

Extension leads are some of the most frequently failed items on any site. They are moved constantly, stretched, kinked and left plugged in for years. Common faults are loose or damaged plugs and sockets, heat damage from running heaters or kettles through them, and failed earth continuity, where the earth connection that protects you has broken somewhere along the lead.

An extension lead is a temporary connection. If one has been in the same spot for years, that is a sign you need a power point installed there by an electrician.

Power boards, power packs and appliances

Faulty power board that failed electrical testing during test and tag
A power board that passed a quick look but failed electrical testing

Power boards are the reason electrical testing matters as well as the visual check. A board can look perfectly fine on the outside and still fail insulation or earth tests because of internal damage, heat or moisture. Cheap boards and boards that have been daisy-chained into other boards are frequent offenders.

Faulty power board removed from service after test and tag
A faulty power board tagged out of service
Faulty power pack that failed test and tag
A faulty power pack Plug in adaptors and chargers need testing too

Power packs, chargers and plug-in adaptors are easy to overlook because they are small. They still connect to 240 volts, and damaged ones can overheat. The same goes for everyday appliances.

Faulty electrical appliance that failed test and tag
A faulty appliance found during a routine test and tag visit

What happens when an item fails test and tag?

  1. It is tagged out of service. The item gets an out-of-service tag so nobody keeps using it.
  2. It is listed on your register. Every failed item is recorded with its location and the reason it failed, so you know exactly what needs attention.
  3. You decide: repair or replace. Repairs to electrical equipment should be done by a licensed electrician. For cheap items such as extension leads and power boards, replacement is usually the sensible choice.
  4. Repaired items are retested before they go back into use.

How to reduce test and tag failures between tests

  • Ask staff to look at leads and plugs before use and report damage straight away.
  • Keep leads off the floor in workshops and away from vehicle and trolley paths.
  • Do not daisy-chain power boards or run heaters through extension leads.
  • Replace cheap power boards with good-quality boards with overload protection.
  • Stick to the right testing interval for your environment. Workshops and factories need more frequent testing than offices. See our guide: how often does test and tag need to be done in Victoria?

Book a test and tag

Shortcut Computers provides qualified test and tag to AS/NZS 3760 across Frankston, the Mornington Peninsula, Casey, Cranbourne, Dandenong and the surrounding suburbs, including 3-phase equipment, out-of-hours testing and a full asset register on completion. Contact us with a rough item count and your type of workplace for a quote.

author avatar
Steve Trim
Steve Trim has worked in business IT since 1993 and provides practical support across Microsoft 365, business networks, data cabling, CCTV, WiFi, Starlink, backup and Test & Tag services in South East Melbourne and the Mornington Peninsula.

Need help with this in your business? Shortcut Computers provides business IT support, registered data cabling, licensed CCTV, WiFi, NBN troubleshooting and qualified Test & Tag on-site across 41 suburbs in South East Melbourne and the Mornington Peninsula, from our base in Langwarrin.

Call now Get a quote